Houses in multiple occupation standards

The legal minimum standards are contained in Statutory Instrument 2006 No 373, with amendments contained in Statutory Instrument 2007 No 1903. These standards apply to all HMO, whether or not they need to be licensed.

The standards set out in Statutory Instrument 2006 No 373, schedule 3 stipulate the following:

  • An adequate means of space heating must be provided in each letting and in bathrooms, whether shared or not
  • Kitchens and bathrooms must be adequately ventilated, including extractor fans in kitchens
  • Kitchens, bathrooms and toilets must be of adequate size and layout and be suitably located in the HMO in relation to the lettings
  • All baths, showers, wash hand basins and sinks must be fitted with taps supplying cold water and a constant supply of hot water
  • For up to 4 occupiers, there must be at least one bathroom and toilet (which can be in the bathroom). This has been amended by Statutory Instrument 2007 No 1903 to say that there must be an adequate number of bathrooms, toilets and wash hand basins for personal washing for the number of persons sharing those facilities, and where reasonably practicable there must be a wash hand basin with appropriate splash back in each unit.
  • For five or more occupiers, there must be at least one bathroom for every 5 sharers, and a separate toilet for every 5 sharers. This has been amended by Statutory Instrument 2007 No 1903 to say that there must be an adequate number of bathrooms, toilets and wash hand basins for personal washing for the number of persons sharing those facilities, and where reasonably practicable there must be a wash hand basin with appropriate splash back in each unit.
  • Adequate size and layout kitchen for the number of sharers, containing sinks with draining boards, cooking equipment, worktops, storage cupboards, for food and crockery and utensils, fridge/freezers (combined or separate), and electrical sockets
  • Adequate refuse disposal facilities
  • Adequate fire precautions including fire doors and fire blankets as appropriate

We use a set of recommended standards which will satisfy these legal requirements. Officers will also assess the property against the Housing Health and Safety Rating System and will take the appropriate enforcement action to ensure any deficiencies are rectified.

Heating

The normally accepted standard is a central heating system (preferably gas fired), or fixed heaters (electric heaters should be hard wired, not plugged into the room sockets). Portable electric fires, convector heaters or oil filled radiators, gas cylinder powered heaters or paraffin heaters are not acceptable.

Space

Letting rooms should be not less than 10m2 for a single letting, which can be reduced to 7m2, if there is a communal lounge. Double rooms should be 15m2 and 11m2 respectively.

Natural light and ventilation

Clear glazing equivalent in area to 10% of the floor area of the room should be provided in each letting. Openable windows equivalent in area to 5% of the floor area of the room should be provided in each letting. Doors to open air cannot be included in the reckoning.

Fire Safety

Fire safety provisions and equipment should be provided as appropriate to the accommodation in line with the fire safety in houses recommendations.